Installation, Operation and Maintenance Manual
DOC.IOM.EF.EN Rev. 7
September 2017
EL-O-Matic F-Series
Rack and Pinion Pneumatic Actuators
EL Matic
TM
EL Matic
TM

Table of Contents

Other manuals for Emerson EL-O-Matic F Series

Questions and Answers:

Emerson EL-O-Matic F Series Specifications

General IconGeneral
Temperature Range-20°C to 60°C (-4°F to 140°F)
Materialsstainless steel
Input Voltage24V AC/DC
Output Voltage24V AC/DC
Operating Temperature-20°C to +80°C (-4°F to +176°F) Standard, -40°C to +80°C (-40°F to +176°F) Low Temperature Option
Enclosure RatingIP66
DimensionsVaries depending on model. Consult specific model datasheet.
WeightVaries depending on model. Consult specific model datasheet.

Summary

Section 3: Configuration Code

Understanding the Configuration Code

Explains how to create and interpret the actuator's configuration code.

Section 4: Installation

4.5 Actuator to Valve Installation

Step-by-step guide for mechanically connecting the actuator to a valve.

Section 5: Mechanical Stroke Adjustment

5.1 Travel Stop Adjustment

How to adjust the actuator's travel limits for precise valve positioning.

Section 6: Maintenance

6.1 Normal Maintenance

Routine checks and recommended inspection intervals for actuator upkeep.

6.2 Inspection and Repair

Procedures for inspecting and repairing actuators to extend service life.

Section 7: Decommission (Out of Service)

7.2 Removing the actuator from the valve

Detailed steps for safely disconnecting the actuator from the valve assembly.

Section 8: Disassembly

8.1 Removing End Caps (Sizes 25 to 600)

Procedure for safely removing end caps from specific actuator size ranges.

Section 9: Reassembly

Section 10: Troubleshooting

10.1 Mechanical Problems

Identifies common mechanical issues and provides solutions for them.

10.2 Pneumatic Problems

Addresses pneumatic system issues and their corresponding troubleshooting steps.

10.3 Electrical Problems

Lists common electrical faults and offers solutions for troubleshooting.

Appendix: A Spring load removal

A.1 Spring load relief

Safe procedure for relieving spring load in specific actuator scenarios.

Appendix: C Full Stroke Adjustment Option

C.2 Convert a standard actuator into a Full Stroke Adjustment version

Steps to upgrade a standard actuator with the full stroke adjustment kit.

C.3 Full Stroke Adjustment Setting

Procedures for setting the full stroke adjustment for desired rotation angles.