8.1 Removing End Caps (Sizes 25 to 600)
1. For Double-acting actuators, do the following:
a. Remove the screws (8) and washers (10) of the end caps (6).
b. Remove the o-ring (11) and "B" port seal (2). Discard these parts.
Figure 17 Double-Acting End Caps Removal
2
6
8
6
11
6
5
10
8
10
11
2
Double acting end caps (6) are fitted with a white warning sticker. Spring return end
caps (5) are fitted with a black warning sticker.
The above end caps (5) are for actuator sizes 25, 40, 65 and 100.
End caps (6) for double acting actuator sizes 150 and larger will have flat end caps.