4.4 Actuator Assembly Codes
Figure 7 Assembly Code - Double-Acting
Assembly code: CW Assembly code: CC
= Standard, Clockwise-to-Close rotation = Reverse, Counterclockwise-to-Open
= Fail-to-Close = Fail-to-Open
A = Rotation when central air chamber is pressurized.
B = Rotation when end cap air chambers are pressurized.
All views are from above. Pistons are shown in inward position.
Figure 8 Assembly Code - Spring-Return
Assembly code: CW Assembly code: CC
= Standard, Clockwise-to-Close rotation = Reverse, Counterclockwise-to-Open
= Fail-to-Close = Fail-to-Open