Decommission (Out of Service)
7.2 Removing the actuator from the valve
1. Disconnect all air supply hoses (Ports A and B or solenoid).
2. Disconnect all electrical wirings of the switch box.
3. Disconnect the electrical wiring of the solenoid valve.
4. Remove the bolts and nuts from the valve ange.
5. Remove the bracket from the actuator.
6. Remove the switch box and solenoid valve. Refer to the documentation of the
switch box and solenoid valve for safe disassembly.
Figure 16 Removing actuator from valve