EasyManua.ls Logo

Emerson EWR20V4 - System Control Timing Charts

Emerson EWR20V4
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-14-1 E9400TI
SYSTEM CONTROL TIMING CHARTS
[ VCR Section ]
Mode SW : LD-SW
LD-SW Position detection
A/D Input voltage Limit
(Calculated voltage)
Symbol
3.76V~4.50V
(4.12V)
EJ
4.51V~5.00V
(5.00V)
CL
0.00V~0.25V
(0.00V)
SB
1.06V~1.50V
(1.21V)
TL
0.66V~1.05V
(0.91V)
FB
1.99V~2.60V
(2.17V)
SF
1.51V~1.98V
(1.80V)
SM
3.20V~3.75V
(3.40V)
AU
0.26V~0.65V
(0.44V)
AL
4.51V~5.00V
(5.00V)
SS
2.61V~3.19V
(2.97V)
RS
Note:
Note:
EJ RS: Loading FWD (LM-FWD/REV “H”)
RS EJ: Loading REV (LM-FWD/REV “L”)
Stop (A) = Loading
Stop (B) = Unloading
Note:
Symbol Loading Status
EJ Eject
CL Eject ~ REW Reel
SB REW Reel ~ Stop(B)
TL Stop(B) ~ Brake Cancel
FB Brake Cancel ~ FF / REW
SF FF / REW ~ Stop(M), (FF / REW)
SM Stop(M), (FF / REW) ~ Stop(A)
AU Stop(A) ~ Play / REC
AL Play / REC ~ Still / Slow
SS Still / Slow ~ RS (REW Search)
RS RS (REW Search)

Other manuals for Emerson EWR20V4