The Specications section lists specications for Type Y692 Gas Blanketing Regulator. Specications for a
given regulator as it originally comes from the factory are stamped on the spring case nameplate.
1. The pressure/temperature limits in this Instruction Manual and any applicable standard limitation should not be exceeded.
CONTROL PRESSURE RANGES WITH
CASE BARREL POINTED DOWN
CONTROL SPRING
COLOR CODE
CONTROL SPRING
PART NUMBER
SPRING WIRE
DIAMETER
SPRING FREE
LENGTH
Type psig bar In. mm In. mm
Light Spring
Assembly
1 to 3 in. w.c.
(2)(3)
3 to 11 in. w.c.
(2)(4)
6.5 in. w.c. to 1.2 psig
(5)
0.7 to 2
1 to 3.2
2 to 7 mbar
(2)(3)
7 to 27 mbar
(2)(4)
16 mbar to 0.08 bar
(5)
0.05 to 0.14
0.07 to 0.22
Brown
Iridite
Green
Blue
Orange
1D892527022
0B019727052
0B019427052
0B019627032
0A081127202
0.109
0.148
0.187
0.225
0.250
2.77
3.76
4.75
5.71
6.35
6.12
6.00
6.00
6.00
6.00
155
152
152
152
152
Heavy spring
Assembly
2 to 5.5
4 to 7
0.14 to 0.38
0.28 to 0.48
Metallic with green stripe
Metallic (silver)
0Y066427022
1H802427032
0.363
0.406
9.22
10.3
6.00
6.00
152
152
1. Install with spring case pointing down to achieve low setpoints in these spring ranges.
2. Do not use Fluorocarbon (FKM) diaphragm with these springs at diaphragm temperature lower than 60°F / 16°C.
3. Installation with spring case pointing up will change outlet (control) pressure range to 3 to 5 in. w.c. / 7 to 12 mbar.
4. Installation with spring case pointing up will change outlet (control) pressure range to 5.75 to 14 in. w.c. / 14 to 35 mbar.
5. Installation with spring case pointing up will change outlet (control) pressure range to 7.5 in. w.c. to 1.3 psig / 19 to 90 mbar.
Table 1. Control Pressure Ranges

Direct-operated pressure reducing regulator with
external or internal pressure registration with
seven outlet (control) pressure ranges from
1 in. w.c. to 7 psig / 2 mbar to 0.48 bar.
Available in NPS 1-1/2 and 2 / DN 40 and 50
body sizes.
Body Sizes and End Connection Styles
(1)(2)
Cast Iron: NPS 1-1/2 / DN 40, NPT
NPS 2 / DN 50, NPT or CL125 FF
Steel: NPS 1-1/2 or 2 / DN 40 or 50, NPT, SWE,
CL150 RF, CL300 RF or PN 16/25/40
Stainless Steel: NPS 1-1/2 or 2 / DN 40 or 50, NPT,
CL150 RF, CL300 RF or PN 16/25/40
Maximum Allowable Inlet Pressure
(1)
150 psig / 10.3 bar or body rating limit
Maximum Control (Casing) Pressure
(1)
15 psig / 1.0 bar
Control Pressure Ranges
(1)
See Table 1

See Table 2

See Table 3
Pressure Registration
Internal (standard) or External
Maximum Operating Control Pressure to Avoid
Internal Part Damage
(1)
3 psig / 0.21 bar above control pressure setting
Temperature Capabilities
(1)
Nitrile (NBR): -20 to 180°F / -29 to 82°C
Fluorocarbon (FKM): 0 to 300°F / -18 to 149°C
Ethylenepropylene (EPDM): -20 to 275°F /
-29 to 135°C
 -20 to 300°F /
-29 to 149°C
Spring Case Connection
1/4 NPT
Approximate Weights
Cast Iron Body: 45 lbs / 20 kg
 57 lbs / 26 kg
X
T
F
D
F
L
0.775 0.50 0.89
Table 3. IEC Sizing Coefcients
BODY SIZE ORIFICE SIZE
WIDE-OPEN C
V
WIDE-OPEN C
g
C
1
NPS DN In. mm
1-1/2 and 2 40 and 50
1/4
3/8
1/2
3/4
1
1-3/16
6.4
9.5
13
19
25
30
1.51
3.14
5.43
11.9
20
26
53.0
111.0
190.0
415.0
700.0
910.0
35
Table 2. Orice Sizes and Flow Coefcients
2