3.6.1  Frequency/Digital outputs
The meter has three user-configurable selections for configuring either a
Frequency output or Digital output (FODO).
FODO1 (eight possible parameter configurations) [Type 2] [Type 4]
FODO2 (eight possible parameter configurations) [Type 2] [Type 4]
FODO3 (eight possible parameter configurations) [Type 2] [Type 4]
FODO4 (eight possible parameter configurations) [Type 4]
FODO5 (eight possible parameter configurations) [Type 4]
FODO6 (eight possible parameter configurations) [Type 4]
Frequency or Digital Outputs (FODO 1, FODO 6) source - Group 1
FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
Frequency output 1A is the A Phase of Frequency output 1 content
(Uncorrected volume flow rate, Profile factor)
Frequency output 1B is the B Phase of Frequency output 1 Electrical installation
Frequency output 2A is based on frequency content (Actual - Uncorrected Flow
Rate)
Frequency output 2B is based on frequency content and Frequency 2B Phase
Digital output 1A is based on Digital output1A content (Frequency Output
1Validity and Flow Direction)
Digital output 1B is based on Digital output1B content (Frequency Output 1
Validity and Flow Direction)
Digital output 2A is based on Digital output 2A content (Frequency Output 2
Validity and Flow Direction)
Frequency or Digital Outputs (FODO 2, FODO 3, FODO 4, FODO5) source -
Group 2
FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
Frequency output 1A is the A Phase of Frequency output 1 content
(Uncorrected volume flow rate, Profile factor)
Frequency output 1B is the B Phase of Frequency output 1
Frequency output 2A is the A Phase of Frequency output 2 content
(Uncorrected volume flow rate, Profile factor)
Frequency output 2B is the B Phase of Frequency output 2 content
Digital output 1A is based on Digital output1A content (Frequency Output
1Validity and Flow Direction)
Digital output 1B is based on Digital output1B content (Frequency Output 1
Validity and Flow Direction)
Electrical Installation Installation manual