Unidrive M200-201 Quick Start Guide 45
Issue Number: 6
Defines the upper current threshold for the brake. See Brake Controller Brake Release in Drive User
Guide.
Defines the lower current limit for the brake. See Brake Controller Brake Release in Drive User
Guide.
Defines the Brake Release Frequency. See Brake Controller Brake Release in Drive User Guide.
Defines the Brake Apply Frequency. See Brake Controller Brake Release in Drive User Guide.
Defines the pre-brake release delay. See Brake Controller Brake Release in Drive User Guide.
00.046 {12.042} Brake Controller Upper Current Threshold
RW Num US
OL
Ú
0 to 200 %
Ö
50 %
RFC-A
00.047 {12.043} Brake Controller Lower Current Threshold
RW Num US
OL
Ú
0 to 200 %
Ö
10 %
RFC-A
00.048 {12.044} Brake Controller Brake Release Frequency
RW Num US
OL
Ú
0.00 to 20.00 Hz
Ö
1.00 Hz
RFC-A
00.049 {12.045} Brake Controller Brake Apply Frequency
RW Num US
OL
Ú
0.00 to 20.00 Hz
Ö
2.00 Hz
RFC-A
00.050 {12.046} Brake Controller Brake Delay
RW Num US
OL
Ú
0.0 to 25.0 s
Ö
1.0 s
RFC-A
Unidrive M200 201 Quick Start Guide English Iss6.book Page 45 Thursday, September 10, 2015 1:48 PM