46 Unidrive M200-201 Quick Start Guide
Issue Number: 6
Defines the post-brake release delay.
Defines the initial direction of the brake.
See Brake Controller Brake Release in Drive User Guide.
Defines if the brake is applied through zero threshold. See Brake Controller Brake Release in Drive
User Guide.
00.051 {12.047} Brake Controller Post-brake Release Delay
RW Num US
OL
Ú
0.0 to 25.0 s
Ö
1.0 s
RFC-A
00.053 {12.047} Brake Controller Initial Direction
RW Txt US
OL
Ú
Ref (0), For (1), Rev (2)
Ö
Ref (0)
RFC-A
Value Text
0reF
1For
2Rev
00.054 {12.051} Brake Controller Brake Apply Through Zero Threshold
RW Num US
OL
Ú
0.00 to 25.00 Hz
Ö
0.00 Hz
RFC-A
00.055 {12.041} Brake Controller Enable
RW Txt US
OL
Ú
dis (0), Relay (1), dig IO (2), User (3)
Ö
dis (0)
RFC-A
Value Text
0Dis
1 Relay
2 dig IO
3 USEr