5.10.3 Menu 9 - Ethernet Resources
Table 5.7 Menu 9 parameters
5.10.4 Menu 10 - Easy Mode Cyclic Data
Table 5.8 Menu 10 parameters
Parameter Range Default Type
09.001 Cyclic Tx Links Free 0 to 255 RO Num ND NC
09.002 Cyclic Rx Links Free 0 to 255
RO Num ND NC
09.003 Fieldbus Links Free 0 to 255
RO Num ND NC
09.004 Cyclic Mappings Free 0 to 255
RO Num ND NC
09.008 Background cycles per second 0 to 65535
RO Num ND NC PT
09.010 Synchronous Task % Free 0 to 255 %
RO Num ND NC
09.020 Synchronous Task Worst % Free 0 to 255 %
RO Num ND NC
09.030 PCB Temperature
-128 to 127
o
C
RO Num ND NC
Parameter Range Default Type
10.001 Enable Off (0) or On (1) On (1) RW Bit US
10.002 Reset Off (0) or On (1) Off (0) RW Bit NC
10.003 Default Off (0) or On (1) Off (0) RW Bit NC
10.010 Tx1 Link Profile Std (0), Sync (1) Std (0) RW Txt US
10.011 Tx1 Link Number 0 to 255 0 RW Num US
10.012
Tx1 Source
Parameter
0.00.000 to 4.99.999 0.00.000 RW SMP PT US
10.013
Tx1 Parameter
Count
0 to 10 0 RW Num US
10.014
Tx1 Link
Transmission Type
Unicast (0),
Broadcast (1),
Multicast1 (2),
Multicast2 (3),
Multicast3 (4),
Multicast4 (5)
Unicast (0) RW Txt US
10.015
Tx1 Destination
Address
0.0.0.0 to 255.255.255.255 0.0.0.0 RW IP US
10.016 Tx1 Message Rate 0 to 100 ms 0 ms RW Num US