68 SI-Ethernet User Guide
Issue: 1
This parameter reports the link’s status if it has been loaded. A Reset (S.10.002) is
required to load any changes.
Used to select Rx2 as a standard or synchronous cyclic link.
-13 Msg mismatch Link number and direction do not match
-12 Msg too long Resulting message is too long
-11 Attrib NA Attribute not available
-10 Attrib RO Attribute is read only
-9 Attrib missing Attribute is missing
-8 Timeout Timeout
-7 In error The specified link is in error state
-6 Link num in use The link number specified is already in use
-5 Not editable The link specified is not editable
-4 Invalid link num An invalid link number was specified
-3 Invalid args Link number / argument zero or invalid
-2 Too many links Maximum number of links has been reached
-1 Out of memory Failed to allocate memory
0 OK Configuration of link successful
1 Not running Ok, not running
2 OK sync Configuration of synchronous link successful
S.10.050 Rx2 Link Profile
Minimum 0 Maximum 1
Default 0 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, TE
Value Text Description
0
Std Standard link
1
Sync Synchronized link
Value Text Description