80 SI-Ethernet User Guide
Issue: 1
The parameter displays a count of network errors since startup. It can be used as an
indication of a problem.
This module does not support Slave mode.
This parameter defines the allowable network delay (in milliseconds) for the Easy Mode
synchronous transmit cyclic links to arrive at their destination.
S.11.020 Network Error Count
Minimum 0 Maximum 4294967295
Default Units
Type 32 Bit Volatile Update Rate Written every 500 ms
Display Format None Decimal Places 0
Coding RO, ND, NC, PT, BU
S.11.022 Interoption Sync Status
Minimum 0 Maximum 2
Default Units
Type 8 Bit Volatile Update Rate Background
Display Format None Decimal Places 0
Coding RO, TE, ND, NC, PT, BU
Value Text Description
0 MASTER The module is master but not producing
1 PRODUCER The module is master and producing
2 INDEPENDENT The module is not master
S.11.030 Easy Mode Maximum Network Delay
Minimum 1 Maximum 100
Default 3 Units ms
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, BU
S.11.040 Rx1 Late Synchronisation Frame Action
Minimum 1 Maximum 3
Default 1 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, TE, BU