82 SI-Ethernet User Guide
Issue: 1
Defines the event number to trigger in the given destination (slot) when a late
synchronized frame is received on the Rx1 link.
This parameter defines the action to be taken when a late synchronized frame is
received on the Rx2 link.
Defines the destination (slot) to trigger the event when a late synchronized frame is
received on the Rx2 link.
This feature is not yet implemented.
S.11.050 Rx2 Late Synchronisation Frame Action
Minimum 1 Maximum 3
Default 1 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, TE, BU
Value Text Description
1 Trip Trip drive with Slx.Er and sub-trip code
2 Do not use The data is ignored
3 Use The data is used immediately
S.11.051 Rx2 Late Synchronisation Frame Destination
Minimum 0 Maximum 4
Default 0 Units
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, TE, BU
Value Text Description
0 This slot Trigger module event in this slot
1 Slot 1 Trigger module event in slot 1
2 Slot 2 Trigger module event in slot 2
3 Slot 3 Trigger module event in slot 3
4 Slot 4 Trigger module event in slot 4
This feature is not yet implemented.