EasyManua.ls Logo

Emerson VSX4 Series User Manual

Emerson VSX4 Series
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
VSX4 and VSX8 Series Controller
!
WARNING
Failure to follow these instructions or to
properly install and maintain this equipment
could result in an explosion and/or fire
causing property damage and personal
injury or death.
Fisher™ controller must be installed, operated
and maintained in accordance with federal,
state and local codes, rules and regulations
and Emerson Process Management Regulator
Technologies, Inc. (Emerson) instructions.
Only a qualified person must install or
service the VSX4 and VSX8 Series controller.
If a leak develops or if the controller
continually vents gas, service to the unit may
be required. Failure to correct trouble could
result in a hazardous condition.
Installation, operation and maintenance
procedures performed by unqualified
personnel may result in improper adjustment
and unsafe operations which may result in
equipment damage or personal injury.
The VSX4 and VSX8 Series controller do
not activate in response to fire, seismic and
lightning events.
Figure 1. VSX4 and VSX8 Series Controller
Introduction
Scope of the Manual
This Instruction Manual provides installation, adjustment,
maintenance and parts ordering information for the VSX4
and VSX8 Series controller. Instructions for other equipment
used with the controller, such as pressure regulators, can be
found in separate instruction manuals.
Table of Contents
Introduction ..................................... 1
Specifications ................................... 2
Principle of Operation ............................. 4
Installation ...................................... 6
Dimensions ..................................... 7
Reed Switch .................................... 8
Startup and Shutdown ............................. 8
Commissioning .................................. 8
Controller Spring Adjustment ........................ 8
Maintenance ................................... 12
Parts Ordering .................................. 13
Parts List ...................................... 14
VSX4 and VSX8 Series
Instruction Manual
D103127X012
May 2018
Question and Answer IconNeed help?

Do you have a question about the Emerson VSX4 Series and is the answer not in the manual?

Emerson VSX4 Series Specifications

General IconGeneral
BrandEmerson
ModelVSX4 Series
CategoryController
LanguageEnglish

Summary

VSX4 and VSX8 Series Specifications

Principle of Operation

Controller Mechanism Explanation

Explains how the diaphragm senses downstream pressure and controls gas flow via springs and valve plug.

Installation Guide

General Installation Instructions

Provides essential guidelines for safe and proper installation, including vent handling and protection.

Reed Switch Functionality

Operational Procedures

Controller Adjustment and Setpoints

Covers spring adjustment and OPSO/UPSO setpoint adjustments for controller operation.

Manual Shut-Off Button Procedure

Controller Status and Maintenance

Systematic Maintenance Overview

Recommendations for periodic inspection, testing, and troubleshooting of the shut-off mechanism.

Maintenance Procedures

Valve Plug (Disk) Replacement

Instructions for replacing the valve plug (disk) in VSX4 and VSX8 Series controllers.

Related product manuals