48 Programming instructions and menu list Emotron AB 01-3991-11r2
Parameter function list
Basic menu function list
Ta bl e 2 3
Menu Function Description Range/ Code
Factory
Default
Remarks
Preferred view
110
Status display parame-
ters
000: No display
001: Display
000 *1
Main setup, Operation
211 Control mode
000: Vector control
001: V/F Control
000 *4
212
Frequency command
source
000: Up/Down key on control panel
001: Potentiometer on control panel
002: AIN input signal from (TM2)
003: Multi-function input terminal Up/
Down function
004: RS-485 Communication frequency
setting
000
213 Run command source
000: Keypad
001: External Terminal
002: Communication control
000
214 Reset mode
000: RUN instruction is OFF, Reset com-
mand is available.
001: Whether RUN instruction is OFF or
ON, Reset command is available.
000
215
Local/Remote fre-
quency control select
(Run command by the
Run/Stop key)
000: Up/Down key on keypad sets fre-
quency
001: Potentiometer on the keypad set fre-
quency
000
216 Reverse run instruction
000: Reverse enable
001: Reverse disable
000
217 Fan control
000: Auto-run at set temperature
001: Run when VSD runs
002: Always run
003: Always stop
001