64 Software index Emotron AB 01-3990-11r3
Note: 1. Energy Saving Mode is available only in Volts/Hz Mode (0-00 = 0002).
3-18 Copy Unit
0000: Disable
0001: VSD to Copy Unit
0002: Copy Unit to VSD
0003: Verify
0000
3-19 Fan Control
0000: Auto (depends on
temp.)
0001: Operate while in
RUN mode
0002: Always Run
0003: Always Stop
0000
3-20 Energy Saving Mode *
1
0000: Disabled
0001: Controlled by
MFIT at Set Frequency
0000 *6
3-21 Energy Saving Gain (%)*
1
0 to 100 80 *6
3-22 Carrier Frequency (kHz) 2 to 16 10
3-23
Centre Frequency (CF) of
Traverse Run (%)
5.00 to 100.00 20.00
3-24
Amplitude (A) of Traverse
Run (%)
0.1 to 20.0 10.0
3-25 Drop (D) of Traverse Run (%) 0.0 to 50.0 0.0
3-26
Acc Time (AT) of Traverse
Run (s)
0.5 to 60.0 10.0
3-27
Dec Time (DT) of Traverse
Run (s)
0.5 to 60.0 10.0
3-28
Rise (X) Deviated Traverse
(%)
0.0 to 20.0 10.0
3-29
Lower (Y) Deviated Traverse
(%)
0.0 to 20.0 10.0
3-30 Start Frequency (Hz) 0.00 to 10.0 0.0
Function
Code no.
Description Range/Code
Factory
setting
Re-
marks