EasyManua.ls Logo

EMX KPX-100 - Advanced Programming Settings; False Key Lock-Up and Reporting; Door Forced Open Alarm Settings

EMX KPX-100
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EMX Industries, Inc. Tech support: 216-518-9889 6/9
Document No.10579100 Rev 2.5 technical@emxinc.com
False Key Lock-Up & Reporting
7 0
1 #
7 0
2 #
7 0
5-10
#
8 5
3 #
After 10 successive false keys, keypad locks for
30 seconds. (default)
After 10 successive false keys, duress output activates.
Keypad locks for 15 minutes after specified number (5-10) of false
keys. Locking is released with user super key followed by #9.
Clears all lock-up and reporting codes.
Door Forced Open Alarm
8 0
0 #
8 0
1 #
Nothing occurs when the door is forced open. (default)
Alarm sounds for 60 seconds when the door is forced open. Output
through terminal 13.
Correct Key Entry Tones
8 1
0 #
8 1
1 #
8 1
2 #
Keypad does not beep upon correct key entry.
Keypad beeps twice upon correct key entry.
Keypad beeps once upon correct key entry. (default)
User Key Entry Mode
8 2
0 #
8 2
1 #
Requires # after user key is entered. (default)
Keypad does not require # after user key is entered. All user keys
must match Programming key length.
Keystroke Tones
8 3
0 #
8 3
1 #
Keystrokes are silenced.
Keypad beeps on every keystroke. (default)
Orange LED Standby
8 4
0 #
8 4
1 #
Orange LED is OFF during system standby.
Orange LED flashes during system standby. (default)
Door Propped Open Alarm
9
0 #
9
1-999
#
No alarm for a propped open door.
Alarm sounds for a propped open door after the specified time (1-999
seconds).

Related product manuals