EasyManua.ls Logo

EMX KPX-100 - User Manual

EMX KPX-100
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EMX Industries, Inc. Tech support: 216-518-9889 1/9
Document No.10579100 Rev 2.5 technical@emxinc.com
KPX-100
Programmable Keypad
Instruction Manual
The KPX-100 is a dual relay output, programmable keypad. It features a durable metal housing
and metal backlit keys designed for high traffic areas and harsh environments.
Connect this keypad to door strike controls, security systems or automatic gate and door operators.
The KPX-100 easily mounts on gooseneck stands, posts or walls.
Power 12-24 VDC/AC
Standby Current 16 mA
Detection Current 78 mA
Environmental Rating IP66
Operating Temperature -4º to 158ºF (-20º to 70ºC) 5 to 95% relative humidity
Housing Material Powder coated steel with stainless steel faceplate
Dimensions (L x W x H)
6.14” (156
mm) x 4.1” (103
mm) x 2.76”
(50
mm)
Specifications
Status Tones Left LED Orange LED Right LED
Programming Mode --- --- Flashes ---
Successful Key Entry Relay 1
Determined by
code 81
--- 1 flash
Solid green
LED
Successful Key Entry Relay 2
code 81
Solid red LED 1 flash ---
Unsuccessful Key Entry 5 beeps --- 3 flashes ---
Successful Code Entry 2 beeps --- 2 flashes ---
Unsuccessful Code Entry 5 beeps --- 5 flashes ---
DAP Jumper Not Replaced
Continuous
beeps
--- Flashes continuously ---
Standby Mode --- ---
1 flash every
2 seconds
---
Lock-Up Mode 5 beeps On
1 flash every
2 seconds
Solid red LED
Indicators
TM

Questions and Answers

Summary

KPX-100 Keypad Specifications

Wiring Connections Guide

Power and Output Terminals

Describes power input terminals and normally closed/open contacts for outputs.

Input and Control Terminals

Details egress, duress, common ground, sensor, and inhibit input terminal functions.

Keypad Wiring Diagrams

KPX-100 Keypad Installation

Basic Connections and Programming Entry

Guides initial power connection and entering programming mode.

KPX-100 Programming Options

Programming Mode Entry and Exit

Procedures for entering and exiting the programming mode.

Super User and Duress Key Configuration

Settings for super user keys and duress key activation.

Advanced Programming Settings

False Key Lock-Up and Reporting

Configuration for keypad lock-up and reporting after false key entries.

Door Forced Open Alarm Settings

Options for alarming when a door is forced open.

Egress Delay and Troubleshooting

Troubleshooting Guide

Solutions for common issues, like forgetting the programming key.

Summary

KPX-100 Keypad Specifications

Wiring Connections Guide

Power and Output Terminals

Describes power input terminals and normally closed/open contacts for outputs.

Input and Control Terminals

Details egress, duress, common ground, sensor, and inhibit input terminal functions.

Keypad Wiring Diagrams

KPX-100 Keypad Installation

Basic Connections and Programming Entry

Guides initial power connection and entering programming mode.

KPX-100 Programming Options

Programming Mode Entry and Exit

Procedures for entering and exiting the programming mode.

Super User and Duress Key Configuration

Settings for super user keys and duress key activation.

Advanced Programming Settings

False Key Lock-Up and Reporting

Configuration for keypad lock-up and reporting after false key entries.

Door Forced Open Alarm Settings

Options for alarming when a door is forced open.

Egress Delay and Troubleshooting

Troubleshooting Guide

Solutions for common issues, like forgetting the programming key.

EMX KPX-100 Specifications

General IconGeneral
BrandEMX
ModelKPX-100
CategoryKeypad
LanguageEnglish

Related product manuals