Programming Options
Enter/Exit Programming Mode
Enters programming mode. Orange LED should turn on.
You must enter programming mode to enter any code.
Exits programming mode.
Programming Key *
*
Super User Keys
Owner’s multi-task user key. Can be used to escape from locking mode.
4 5
4-8 digits
#
Duress Keys
4 6
0-9
4-8 digits #
Duress keys activate output 1 and duress outputs
simultaneously to report a user is under duress.
10 duress keys may be used at once.
Visitor Keys
User ID Operation Time
4 7
0-9
00-99
4-8 digits #
10 visitor keys may be used at once.
Operation Time:
00 = one-time use only
01-99 = valid for xx hours
Single User Mode/Reset
*Only use to change modes will erase user codes and
programming code. Must add programming code back after
change*
8 9 0 0 #
Sets the mode and clears all previously stored data and modes. Single
user mode assigns one user key per relay.
Multi-User Mode/Reset
*Only use to change modes will erase user codes and
programming code. Must add programming code back after
change*
8 9 0 1 #
Sets the mode and clears all previously stored data and modes
.
Multi
-
user mode assigns up to 100 user keys for relay 1 and up to 10 user
keys for relay 2.
Relay Output Mode Configuration
Output 1 40
1-999 #
Output 1 41
#
Output 2 50
1-999 #
Output 2 51
#
Momentary Mode:
Keeps OUTPUT 1 triggered for 1-999 seconds upon user key entry.
Start/Stop Mode: Keeps OUTPUT 1 triggered until re-entry of user
key.
Momentary Mode:
Keeps OUTPUT 2 triggered for 1-999 seconds upon user key entry.
Start/Stop Mode: Keeps OUTPUT 2 triggered until re-entry of user
key.
Note: Output 2 may be used as a supervisor mode to disable
Output 1 if wired in series.