EasyManua.ls Logo

ENC EDS300-4T0022 - User Manual

Default Icon
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
0.2-3.7KW
EDS300 Series
Ver.1.1
ISO9001:2015 Quality Management System Authentication
SHENZHEN ENCOM ELECTRIC TECHNOLOGIES CO., LTD
Users’ Manual

Table of Contents

Questions and Answers

  • W
    william59Aug 8, 2025
    What to do if my ENC Inverter shows over current during accelerating?
    • S
      Samantha McfarlandAug 8, 2025
      If the ENC Inverter displays an overcurrent error during acceleration, it could be due to several reasons. The accelerating time might be too short, in which case you should prolong the accelerating time. It may also be due to an improper V/F curve, so adjust the V/F curve setting, adjust manual torque boost, or change to automatic torque boost. If the motor is restarting while rotating, set the speed checking restart function. Check the input power supply in case of low power source voltage. Finally, the inverter's power might be insufficient, so choose an inverter with higher power.
  • T
    Thomas JohnsonAug 12, 2025
    What to do if my ENC Inverter shows over current during constant speed?
    • T
      Taylor AndersonAug 12, 2025
      If the ENC Inverter shows an overcurrent during constant speed, it might be due to a sudden load change or unwonted phenomena; check or reduce the load. If the acceleration/deceleration time is set too short, prolong the accelerating/decelerating time appropriately. Check the input power supply for low voltage. If the inverter's power is insufficient, select a higher-power inverter.
  • D
    Douglas RamirezAug 18, 2025
    What to do if my ENC Inverter shows over current during decelerating?
    • G
      Gina HayesAug 18, 2025
      If the ENC Inverter shows overcurrent during deceleration, the decelerating time may be too short, so prolong it. If there's potential energy load or big inertia load, increase the braking power of the external energy consumption braking subassembly. If the inverter's power is a bit small, choose an inverter with high-power.
  • A
    Anthony CobbAug 23, 2025
    Why is my ENC Inverter showing overvoltage during accelerating?
    • R
      ryanwhiteAug 23, 2025
      If your ENC Inverter is showing overvoltage during acceleration, it could be due to a few reasons. First, check the input power supply for unwonted input voltage. Also, the acceleration time might be set too short, so prolong the accelerating time properly. Finally, if the motor is restarting while rotating, set the speed checking restart function.
  • E
    Elizabeth GrantAug 28, 2025
    What to do if my ENC Inverter shows overvoltage during decelerating?
    • V
      Veronica PriceAug 28, 2025
      If the ENC Inverter shows overvoltage during deceleration, the decelerating time may be too short, so prolong the decelerating time. If there is potential energy load or big inertia load, increase the braking power of external energy consumption braking subassembly.
  • A
    anita24Sep 1, 2025
    How to fix ENC Inverter protection?
    • R
      Rachel DunnSep 2, 2025
      If the ENC Inverter is under protection, it might be due to a blocked air-path or a damaged fan. To resolve this, clear the air-path or replace the fan.

Summary

Safety Information and Use Notice Points

Safety Precautions

Details three types of safety warnings and provides 10 operational and installation precautions for the inverter.

Use Notice Points

Covers normal phenomena, low-speed operation, lubrication, vibration, hoist loads, and switching advice for inverter use.

Type and Specification of the Inverter

Product Technic Index and Spec.

Lists detailed technical specifications for input, output, control modes, performance, and running functions of the inverter.

Installation and Wiring

Installation Ambient

Specifies required environmental conditions for inverter installation, including temperature, humidity, and ventilation.

Wiring Notice Points

Provides essential safety precautions and guidelines for correctly wiring the inverter to prevent damage or injury.

Main Loop Terminal Wiring

Provides a table and diagrams for main loop input/output terminal connections across different adapted inverter types.

Basic Running Wiring Diagram

Shows a schematic for basic inverter operation wiring, including control signals, speed commands, and communication ports.

Control Loop Collocation and Wiring

Guides on connecting and configuring the control loop, terminals, and switches on the inverter's CPU board.

Location & Function of Terminal and Jump-wire

Details the location and function of terminals and switches on the inverter's CPU board for proper setup.

Function Parameter Schedule Graph

Function Parameter Schedule Graph

Presents detailed function parameter groups (F0-F9) with set ranges, factory defaults, and modification status.

Trouble Shooting

Failure and Countermeasure

Lists common failure types (E001-E023), their possible causes, and recommended countermeasures for the inverter.

Fault Reset

Provides instructions for resetting the inverter after a fault, including necessary precautions and delay times.

Maintenance

Routine Maintenance

Outlines daily and periodic inspection items and criteria for routine inverter maintenance to ensure stable operation.

Modbus Communication Protocol

RTU Communication Mode

Details the RTU communication mode, including data frame format, structure, and command codes for parameter access.

Appendix A Serial Port 485 Communication Protocol

Appendix B Braking Resistance

Braking Resistance

Explains the function of braking resistance in managing motor's potential energy and provides a configuration table for external resistances.