EasyManua.ls Logo

ENDA ETC4420 User Manual

ENDA ETC4420
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ETC4420-E-02-R
1/4
ENDA ETC4420 PID TEMPERATURE CONTROLLER
Read this document carefully before using this device. The guarantee will be expired by
damaging of the device if you don't attend to the directions in the user manual. Also we don't
accept any compensations for personal injury, material damage or capital disadvantages.
Thank you for choosing ENDA ETC4420 temperature controller.
* 48 x 48mm sized.
* Selectable sensor type.
* Soft-Start.
* Automatic calculation of PID parameters (SELF TUNE).
* Selectable Heat/Cool control.
* Communication vai RS-485 ModBus protocol (Optional).
* Relay output can be programmable as second alarm or control output.
* AL1 relay output for first alarm out.
* Input offset feature.
* In the case of sensor failure relay state can be
selected.
periodical running or
* Parameter access protection on 3 levels.
* Programming by using keypad or Modbus.
* CE marked according to European Norms.
* Selectable SSR or relay control output.
Enter PID parameters of the system if they are known at the beginning.
Otherwise, Self-Tune should be activated.
J (Fe-CuNi) Thermocouple
K (NiCr-Ni) Thermocouple
T (Cu-CuNi) Thermocouple
S (Pt/0Rh-Pt) Thermocouple
R (Pt13Rh-Pt) Thermocouple
EN 60584
EN 60584
EN 60584
EN 60584
EN 60584
0... 600
0...1200
0... 400
0...1600
0...1600
°C
°C
°C
°C
°C
+32... +1112
+32... +2192
+32... +752
+32... +2912
+32... +2912
°F
°F
°F
°F
°F
Pt 100 Resistance Thermometer
Pt 100 Resistance Thermometer
EN 60751
EN 60751
-200...600
-99.9...300.0
°C
°C
0,2% ( )of full scale
0,2% ( )of full scale
1 digit
1 digit
0,2% ( )of full scale 1 digit
0,2% ( )of full scale 1 digit
0,2% ( )of full scale 1 digit
0,2% ( )of full scale
1 digit
0,2% ( )of full scale 1 digit
-328... +1112
-99.9...+543.0
°F
°F
°C
°F
OUTPUTS
Selectable as Control or Alarm2 output. Relay : 250V AC, 2A ( for resistive load), NO/NC.
Selectable logic control output. (Max 12V 20mA(
(Alarm1 output). Relay : 250V AC, 2A ( for resistive load), NO/NC selectable.
AL1
SSR out
Mechanical 30.000.000 operation; Electrical 300.000 operation
Life expectancy for relay
CONT./AL2
TECHNICAL SPECIFICATIONS
Input type Temperature range
Accuracy
ENVIRONMENTAL CONDITIONS
Height
Max. 2000m
80 up to 31 decreasing linearly 50 at 40 . % %
Ambient/storage temperature
Max. Relative humidity
0 ... +50 / °C -25... +70°C (with no icing)
°C °C
Rated pollution degree
According to EN 60529 Front panel : IP65
Rear panel : IP20
Do not use the device in locations subject to corrosive and flammable gases.
ELECTRICAL CHARACTERISTICS
Supply
230V AC +10 -20 , 50/60Hz or 24V AC ±10 , 50/60Hz.% % %
Power consumption
Max. 5VA
2.5mm² screw-terminal connections
Wiring
Line resistance
Data retention
EMC
Safety requirements
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B for standard EN 61000-4-3)
EEPROM (minimum 10 years)
EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)
For thermocouple max.100ohm, for 3 wired Pt 100 max. 20ohm
CONTROL
Control type Single set-point and alarm control
On-Off / P, PI, PD, PID (selectable)
Control algorithm
A/D converter
15 bits
Sampling time
Proportional band
Derivative time
Integral time
Control period
Hysteresis
Output power
500ms
Adjustable between 0 and 100 . If Pb=0 , On-Off control is selected.% % %
Adjustable between 0.0 and 100.0 minutes
Adjustable between 0.00 and 25.00 minutes
and 250 secondsAdjustable between 1
1 and 50 Adjustable between °C/F
The ratio of power at a set point can be adjusted between 0 and 100% %
HOUSING
Housing type
Suitable for flush-panel mounting according to DIN 43 700.
Dimensions
W48xH48xD87mm
Weight
Approx. 250g (after packing)
Self extinguishing plastics.
Enclosure material
While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.
TEMPERATURE CONTROLLER
ENDA
PV
SV
CSET
ASET
SET
ETC 4420
CNT/AL2
AL1
SSR
Question and Answer IconNeed help?

Do you have a question about the ENDA ETC4420 and is the answer not in the manual?

ENDA ETC4420 Specifications

General IconGeneral
Frequency50/60Hz
Dimensions48x48x100 mm
Input TypeThermocouple, RTD
OutputRelay, SSR
Control ModePID, On/Off
Display4-digit 7-segment LED
Operating Temperature0 to 50 °C
ProtectionIP20
Weight150g

Summary

Technical Specifications and Environmental Conditions

Input Type and Specifications

Details sensor types (Pt 100, J, K, T, S, R) with their temperature ranges and accuracy specifications.

Environmental Operating Conditions

Specifies ambient/storage temperature, relative humidity, pollution degree, and operating height limits.

Electrical Characteristics and Outputs

Electrical Supply and Consumption

Covers power supply voltage, consumption, wiring, line resistance, data retention, EMC, and safety requirements.

Output Specifications

Details the CONT./AL2 relay, AL1 relay, SSR output, and relay life expectancy.

Control Parameters and Housing

Control Settings

Lists control types, algorithms (On-Off, P, PI, PD, PID), A/D converter, sampling time, and timing parameters.

Housing and Dimensions

Describes housing type, panel cut-out dimensions, overall size, weight, and enclosure material.

Parameter Programming and Self-Tune

Parameter Modification Guide

Explains how to modify parameters like Proportional band, Integral time, Derivative time, and Control period.

Self-Tune Procedure

Details the steps and conditions for initiating and performing the PID auto-tune (SELF TUNE) function.

Input Type and Security Settings

Covers input type selection, unit settings, offset values, and security access code for parameter protection.

Alarm Output Types and Set Point Modification

Alarm Output Functions

Illustrates Independent, Deviation, Band, and Band with Inhibition alarm logic for Alarm1 and Alarm2.

Modifying Control and Alarm Set Points

Provides instructions on adjusting Control Set Point (C.SEE) and Alarm Set Points (A 1.SE, A2.SE) using keypad operations.

Device Dimensions and Connection Diagram

Device Physical Dimensions

Shows the external dimensions, panel cut-out size, and depth of the ETC4420 controller.

Wiring and Installation Diagram

Illustrates the connection diagram for power supply, sensor input, and outputs, including safety notes.

Order Code Explanation

Details how to interpret the order code for selecting supply voltage and Modbus option.

Related product manuals