Liquiphant M FTL50(H), FTL51(H)
Endress+Hauser 31
Process connections Parallel thread G ¾, G 1 to DIN ISO 228/I with flat seal to DIN 7603
Tapered thread R ¾, R 1 to EN10226
Tapered thread ¾ -14 NPT, 1 - 11½ NPT to ANSI B 1.20.1
Flush-mounted with welding neck to factory standard Endress+Hauser (G ¾, G 1)
Flush-mounted with welding neck to factory standard Endress+Hauser (1"),
Sensor can be positioned
Tri-Clamp 1½", 2" to ISO 2852
Threaded pipe joint DN 32, 40, 50 to DIN 11851
Aseptic connection DN 50 to DIN 11864-1 Form A for pipe DIN 11850
SMS connection 2" (DN 51)
–DRD flange
Varivent
®
DN 50 (50/40) to factory standard Tuchenhagen
Flanges to EN/DIN from DN 25, for standards see "Product structure", to ANSI B 16.5 from 1",
to JIS B2220 (RF)
Human interface
Electronic inserts
With FEL51, FEL52, FEL54, FEL55:
2 switches for safety mode and density change,
green LED to indicate operational status,
red LED to indicate the switching status,
flashes in the event of corrosion damage
on sensoror if the electronics are defect
With FEL56:
2 switches for safety mode and density change,
green LED flashes to indicate operational status,
red LED to indicate the switching status,
flashes in the event of corrosion damage
on sensor or if the electronics are defect
With FEL57:
2 switches for density change and cyclical checking,
green LED to indicate operational status,
yellow LED to indicate the covered status,
flashes in the event of corrosion damage
on sensor or if the electronics are defect
With FEL58:
2 switches for safety mode and density change,
green LED
flashes quickly to indicate operational status,
flashes slowly to indicate corrosion damage
at the sensor or if the electronics are defect,
yellow LED to indicate the switching status,
Test key – breaks the cable connection
L00-FTL5xxxx-03-05-xx-en-001
L00-FTL5xxxx-03-05-xx-xx-013
With FEL50A:
8 switches for configuring the device address,
green LED to indicate operational status,
pulsing to indicate communication;
yellow LED to indicate the switching status,
flashes in the event of corrosion damage on sensor
or if the electronics are defect
L00-FTL5xxxx-03-05-xx-en-002
Min
Max1
2
>0,7
>0,5
FEL51
12
L1 N
U~
19...253V AC
50/60Hz
I max : 350mA
Connecting terminal LEDs Switches
HW
OFF
ON
Address
SW
12345678
FEL50A
12
PA PA+
Connecting terminal LEDs Switches

Table of Contents

Other manuals for Endress+Hauser Liquiphant M FTL50