Operating Instructions
Liquicap M FTI51, FTI52
Capacitive level limit switch

Table of Contents

Other manuals for Endress+Hauser Liquicap M FTI51

Questions and Answers

  • D
    Donald MillerAug 12, 2025
    What to do if Endress+Hauser Switch does not switch?
    • A
      Andrea BarnesAug 12, 2025
      If your Endress+Hauser Switch isn't switching, first check the connection and ensure the supply voltage is correct. This should resolve the issue.
  • W
    Wesley PowersAug 16, 2025
    Why is the alarm LED flashing on my Endress+Hauser Switch?
    • L
      Laura BarnesAug 16, 2025
      If the alarm LED on your Endress+Hauser Switch is flashing, it could be due to the ambient temperature of the electronics being outside the permitted range, or the connection to the probe being interrupted. Check these two potential causes to resolve the issue.
  • W
    William ArmstrongAug 19, 2025
    What to do if Endress+Hauser Switch has an internal fault?
    • J
      Jason Andrews MDSep 12, 2025
      If your Endress+Hauser Switch has an internal fault, it indicates that the device is defective.
  • M
    Megan RiceAug 23, 2025
    What to do if the DC PNP output is overloaded on Endress+Hauser Switch?
    • D
      dwilliamsAug 23, 2025
      If the DC PNP output of your Endress+Hauser Switch is overloaded, reduce the connected load to resolve the issue.
  • A
    Amy PerkinsAug 27, 2025
    What to do if calibration points are outside the measuring range on Endress+Hauser Switch?
    • S
      Samantha MitchellAug 27, 2025
      If the calibration points of your Endress+Hauser Switch are outside the measuring range, recalibrate the device.
  • S
    Shawn UnderwoodAug 30, 2025
    What to do if Sensor DAT (EEPROM) data are invalid on Endress+Hauser Switch?
    • C
      Cindy HessAug 30, 2025
      If the Sensor DAT (EEPROM) data are invalid on your Endress+Hauser Switch, perform a download from the electronic insert.
  • M
    Michael ThomasSep 3, 2025
    What to do if the calibration point is too close to the measuring range limit on Endress+Hauser Switch?
    • D
      David MartinezSep 4, 2025
      If the calibration point on your Endress+Hauser Switch is too close to the measuring range limit, reduce the switch point or select a new installation location.
  • A
    Alyssa SmithSep 7, 2025
    What to do if Endress+Hauser Switch probe is not detected?
    • M
      mikedouglasSep 7, 2025
      If the probe is not detected by your Endress+Hauser Switch, it may be incompatible. Use a Liquicap M probe.

Summary

Safety Instructions

Identification

2.1.2 Ordering Information (FTI51)

Provides detailed ordering information for the Liquicap M FTI51 model.

2.1.3 Ordering Information (FTI52)

Provides detailed ordering information for the Liquicap M FTI52 model.

Installation

Wiring

4.2 Housing Wiring Procedures

Details wiring steps for common housing types F16, F15, F17, and F13.

4.6 Electronic Insert FEI51 Wiring

Specific wiring instructions for the FEI51 electronic insert (AC 2-wire).

4.10 Electronic Insert FEI55 Wiring (SIL)

Specific wiring instructions for the FEI55 electronic insert, including SIL capabilities.

Operation

5.1 Human Interface and Display Elements (FEI51, FE152, FEI54, FEI55)

Describes the operation interface, function switch, keys, and LEDs for specific electronic inserts.

5.2 Human Interface and Display Elements (FEI53, FEI57 S)

Describes the operation interface, DIP switches, and LEDs for FEI53 and FEI57S inserts.

Commissioning

6.2 Commissioning Electronic Inserts (FEI51-FEI55)

Guides the commissioning process for electronic inserts FEI51, FE152, FEI54, and FEI55.

6.2.2 Setting the Measuring Range

Details how to set the measuring range for the device.

6.2.3 Empty Calibration Procedure

Explains the step-by-step process for performing an empty calibration.

6.2.4 Full Calibration Procedure

Explains the step-by-step process for performing a full calibration.

Troubleshooting

9.1 Fault Diagnostics

Guides users on how to perform fault diagnostics on the electronic insert.