Liquicap M FTI51, FTI52 Wiring
Endress+Hauser 45
4.4 Connecting the device
Connection compartment
Five types of housing are available:
L00-FMI5xxxx-04-00-00-xx-001
!
Note!
The nameplate contains important device data.
Cable entry
Cable gland: M20x1.5 (for EEx d, cable entry only) A second cable gland is included with every
device.
Cable entry: G ½ or NPT ½, NPT ¾
4.5 Degree of protection
* As per EN60529
** As per NEMA 250
Standard EEx ia EEx d Gas-tight process seal
Plastic housing F16 X X - -
Stainless steel housing F15 X X - -
Aluminum housing F17 X X - -
Aluminum housing F13 X X X X
Aluminum housing T13
(with separate connection
compartment)
XXXX
–+
+
FEI5x
4...20 mA
1 2
+
+
T13F15F16 F17/F13
IS - Ground
–+
12
FEI5x
FEI5x
FEI5x
IP66* IP67* IP68* NEMA 4X**
Polyester housing F16 X X - X
Stainless steel housing F15 X X - X
Aluminum housing F17 X X - X
Aluminum housing F13
with gas-tight process seal
X- XX
Aluminum housing T13
with gas-tight process seal and
separate connection compartment (EEx d)
X- XX