Liquicap M FTI51, FTI52 Technical data
Endress+Hauser 85
10.7 Operating conditions: Process
10.7.1 Process temperature range
!
Note!
The following process temperature ranges only apply for standard applications outside hazardous areas.
Regulations for use in hazardous areas are provided in the Supplementary Documentation XA389F/00.
With compact housing
The following diagram applies to:
Rod and rope version
Insulation: PTFE, PFA, FEP
L00-FMI5xxxx-05-05-xx-xx-013
T
a
: Ambient temperature
T
P
: Process temperature
!
Note!
Restriction to T
a
–40 °C for polyester housing F16.
If additional option B is selected (free from paint-wetting impairment substances), the minimum
ambient temperature T
a
is –40 °C. (Only relevant for FTI51!)
T
a
0
0
T
P
–40 –20–60
80 120 160 180
80
60
40
20
–80
–80/
–25
200
–60
–40
–20
20 40 60 100 140
–40/
–40
+20/
–50
+200/
+38
+80/
+70
T
P
T
a
°C