Calculations Tankvision
58 Endress+Hauser
Gives the alcoholic strength by volume as a function of the observe density and
temperature
• Table VIIIA and VIIIB:
Gives the alcoholic strength by mass (Table VIIIA) and the alcoholic strength by volume
(Table VIIIB) as a function of the observe density (density is read from alcoholmeter of
soda lime glass at 20 °C (68 °F)) and temperature. Density at a given temperature is
calculated by the given formula.
• Table IXA and IXB:
Gives the alcoholic strength by mass (Table IXA) and the alcoholic strength by volume
(Table IXB) as a function of the observe density (taken from hydrometer) and temperature
• Table XA and XB
Gives the alcoholic strength by mass (Table XA) and the alcoholic strength by volume
(Table XB) as a function of the observe density (taken from a instrument made of
borosilicate glass) and temperature
• Table XIA and XIB
Calculates volume using alcohol strength by mass (Table XIA) or alcohol strength by
volume (Table XIB)
• Table XIIA and XIIB:
Calculates volume using alcohol strength by mass (Table XIIA) or alcohol strength by
volume (Table XIIB)
Currently Table I, II, IIIA, IVA, VI and VII are implemented in Tankvision NXA820.
L00-NXA82xxx-16-00-00-xx-109