Prosonic S FDU90/91/91F/92/93/95/96
Endress + Hauser 13
Flush mounting with
slip-on flange FAU80
The FDU91F sensor can be flush mounted using a FAU80 slip-on flange. Flanges in polypropylene (PPs) should
only be used with pressures up to 1.5 bar
abs
, flanges in 316L also above.
L00-FDU9xxxx-17-00-00-xx-009
L00-FDU9xxxx-17-00-00-xx-010
The adapter flange is included in the delivery
!
Note!
The process seal is not included in the delivery.
"
Caution!
For 3A applications:
The internal diameter of the nozzle should be selected according to the valid allowable limits for 3A
applications. Usually, the internal diameter of the nozzle should be larger than or equal to the internal diameter
of the sensor.
Order No. Material b [mm] ∅D [mm] ∅d2 [mm] k [mm] No. d2 Standard
FAU80 - CAP PPs
20 200 18 160 8
DN80 PN16
(DIN EN 1092-1-E)
FAU80 - CAJ 316L
FAU80 - AAP PPs
23,9 190,5 19,1 152,4 4
ANSI 3" 150 psi
(ANSI B 16.5)
FAU80 - AAJ 316L
FAU80 - KAP PPs
18 185 19 150 8
JIS10 K80
(JIS B 2220)
FAU80 - KAJ 316L
0,5
A
A
D
k
ø
97.5
d
2
b
ø
81
75.7
d
2
k
ø76
D
ø81
ø130
b
15
75.7
Order No. Material b [mm] ∅D [mm] ∅d2 [mm] k [mm] No. d2 Standard
FAU80 - CHP PPs
20 220 18 180 8
DN100 PN16
(DIN 2527)
FAU80 - CHJ 316L
FAU80 - AHP PPs
23,9 228,6 19,1 190,5 4
ANSI 4" 150 psi
(ANSI B 16.5)
FAU80 - AHJ 316L
FAU80 - KHP PPs
18 210 19 175 8
JIS10 K100
(JIS B 2220)
FAU80 - KHJ 316L