Tx62, TTSP-RT0111, TTSP-CT1121 XA01137T
Endress+Hauser 9
Insert
diameter
Temperature
class
Process temperature
range
1)
Ambient temperature
(housing)
T5 -50 ≤ Tp ≤ +88 °C -40 ≤ Ta ≤ +88 °C
T6 -50 ≤ Tp ≤ +73 °C -40 ≤ Ta ≤ +73 °C
1) Maximum process pressure see relevant Technical Information
Connection data
Type Electrical data
TR62, TC62
TTSP –RT0111, TTSP –CT1121
U ≤ 5 V DC
I ≤ 10 mA
Category Type of protection
(ATEX)
Type
II 2G Ex eb IIC T6...T1 Gb TR62, TC62
TTSP –RT0111, TTSP –CT1121