ML0068-001-02 Container Eject System ENERCON INDUSTRIES
7
SECTION 5 – TROUBLESHOOTING
SYMPTON
CHECK
No power to the control box.
(Seven segment LED’s do not light)
1. Check the input power
2. Is the power switch on at the power entry
module
3. Check the fuse inside the power entry module
4. Remove power and open the box and ensure
the ribbon cable is properly connected between
the display board and the ejector control board
5. Contact Enercon service department for
assistance
Eject plunger does not function
1. Check the eject signal
2. Check for proper inlet air pressure
3. Remove power and open the box and inspect
the hose connections, looking for an open hose
or a kink in a hose.
4. Check solenoid wiring
5. Possible bad solenoid
6. Contact Enercon service department for
assistance
Ejector timing seems to change
1. Are the containers sliding on the conveyor?
2. Is the conveyor speed changing?
3. Check the “bad container” detector for proper
adjustment.
Delay time or eject time are not
adjustable
1. Remove input power and open the box and
ensure the ribbon cable is properly connected
between the display board and the eject control
board
2. Bad display board
3. Bad eject control board
4. Contact Enercon service department for
assistance
*** WARNING ***
BE SURE ALL POWER IS DISCONNECTED
AND LOCKED OUT FROM UNIT BEFORE
PERFORMING CHECK.