IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLANDER IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO
UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
TROUBLE-SHOOTING GUIDE
WARNING: TO AVOID ELECTRICAL SHOCK ALWAYS DISCONNECT THE UNIT FROM THE POWER SOURCE
BEFORE ATTEMPTING ANY REPAIR. IF THIS GUIDE DOES NOT CORRECT THE PROBLEM CALL
YOUR LOCAL DEALER OR OUR TECHNICAL SUPPORT AT 1-877-356-6663.
1. Tighten setscrew on collar
3. Foreign matter in auger
3. Remove pellets and object
4. Vacuum sensor (Top Auger)
5. Carbon buildup in feed auger tube
5. Remove carbon by scraping
2. Smoke smell or dust in house
1. Improper exhaust connection
1. Check all connections for leaks,
especially the exhaust blower
connection; Seal with silicone,
hose clamp or aluminum tape
3. Room air blower not operating
1. Tighten connection on sensor
2. Adjust temperature lower
4. Exhaust blower not operating
1. Check connection at c/board
1. Control board settings
3. Excessive pellet moisture
4. Remove baffles; Clean unit
1. Replace fuse; use surge protector
2. Check for exposed or frayed wire
and loose connections
3. Electric motor shorting or bound
up
3. Check motors and blowers for
obstructions or lock-up
7. High pellet consumption
2. Board out of adjustment
2. Check c/board settings
1. Remove auger and clean
2. Improper auger alignment
9. Pinging or rattling noise
1. Check blower for material
2. Check impeller blower screw
1. Check stove connection
20 to 30 minutes
(E-2 on Control Board)
2. Control board settings
2. Check settings; always start unit
on “5” to “9”setting
3. Failure to start (E-2)
3. Check igniter for buildup
11. Unit keeps shutting down
(“E” codes on control board)
1. Check for flue blockage (nests,
rodents, excess soot, etc.)
2. Check combustion blower wires,
then call Technical Support.
3. Improper installation* (E-1)
3. Check for loose flue/pipe
connections. Also be sure to have
proper Outside Air hook-up.
*Improper installation may cause a back draft.
*NOTE: Also check for loose or cracked vacuum hose on vacuum switches (see #24 in Illustration 6).