EasyManua.ls Logo

Englander 25-PDVC - Specifications; Heating and Compliance Specifications

Englander 25-PDVC
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLANDER IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO
UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
SPECIFICATIONS
Heating Specifications
Approximate Pellet Burn Rate**……1.0 to 1.8 kg/hr (2.2 to 3.8 lbs/hr)
Maximum Burn Time**………………………………………………..20 hours
Approximate Square Footage Heated***………………….up 2,000 sq. ft.
Hopper Capacity (fuel)………………………………………….…..40 pounds
EPA and Safety Compliance Specifications
EPA Compliance Status …………………. Certified to comply with 2020 particulate emission
standards using pellet fuel.
U.S. Test Standard: US EPA 40 CFR Part 60, Subpart 60.536
Heat output range****………….11,220 BTU/h to 26,179 BTU/h (3.29 kW to 7.67 kW)
Particulate Emissions ……………………………………………… 1.430 grams/hr
CO Emissions …………………………………………………………. 0.0 grams/min
Efficiency………………………………………………………………… 68.4 % (HHV)
BTU rating ………………………………………………………………. 26,179 BTU/hr
Certified to ASTM E 1509 / ULC S627/ EPA Test Method ASTM E2779 / CSA B415.1 / ASTM E2515
Notes for this unit: Product may vary slightly from diagram. Clearances are the minimum for
this unit and may need to be increased in the rear to have proper vent clearances. Follow all
venting manufacturer clearances and local codes.
*- As tested per ASTM 2779
** - Heat output, burn rate and maximum burn time are heavily dependent on the type of pellets burned in the stove; as such, these numbers may vary.
*** - The maximum heating capacity of this unit can vary greatly based on climate, construction style, insulation and a myriad of other factors. Use this
information in conjunction with a BTU loss calculation for your home to determine if this unit will be sufficient for your needs.
**** - As measured per CSA B415.1-10 stack loss method.
cleaning and parts and gasket inspection and replacement) can be found at
youtube.com/heatredefined. Click on Playlists to find your stoves model
number to see detailedHow Tovideos.
Also see englander-stoves.com for more information, and call (877) 356-
6663 or email tech@sbi-international.com with questions.