Minimum/Maximum
frequency
f
min
/f
max
Hz 47/68
single/multi-phase
20 A circuit
A/I
acmax
— 8 (240 V L+L)/7 (220 V L+L)
Protective class (all
ports)
— — II
Total harmonic
distortion
— % <5
Power factor setting
— — 1.0
Power factor range cos phi — 0.85 leading … 0.85 lagging
Inverter maximum
efficiency
η
max
% 97.57
CEC weighted
efficiency
η
EU
% 97
Inverter topology — — Isolated (HF transformer)
Nighttime power
loss
— mW 100
MECHANICAL DATA
Ambient air temperature range -40°C to 65°C (-40°F to 149°F)
Relative humidity range 4% to 100% (condensing)
Overvoltage class AC port III
Number of input DC connectors
(pairs) per single MPP-tracker
1
AC connector type
IQ Cabling (refer to separate datasheet for cable and
accessories)
DC connector type Supplied with Stäubli MC4 adapter
Dimensions (H × W × D)
265 mm (10.4") × 200 mm (7.9") × 35 mm (1.4") (without
mounting brackets)
Weight (with mounting plate) 1.6 kg (3.5 lb)
IP rating NEMA Type 6/outdoor - IP67
Maximum altitude <2,600 m (8,530 feet)
Calorific value 59.25 MJ/unit
CA Rule 21 (UL 1741-SB), UL 62109-1, UL1741/IEEE1547, FCC Part
15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01