ENSTROM 280FX OPERATOR’S MANUAL 4-9
FAA Approved: Mar 12/19 Rev. 12
Report No. 28-AC-020 Dec 3/18
e. Tail rotor hub – check security. Check condition of
teeter stop bumpers.
f. Tail rotor blades – check security. Check for cracks
or bond separations. Check strike tabs for evidence
of strike.
21. Left horizontal stabilizer – check condition and
security.
22. Left vertical stabilizer – check condition and security.
23. Left position and anti-collision lights – check security.
24. Left tail cone – check condition.
25. Driveshaft cover – check security and condition.
26. Left static port – unobstructed.
27. Inspection door
a. Belt drive system – engage manual clutch and check
belt tensioning system for proper rigging. Disengage
manual clutch.
b. Cooling fan – check condition.
28. Left fuel tank
a. Check for leaks, check fuel quantity and cap
secured.
NOTE
When checking the fuel quantity, Enstrom
recommends using a calibrated dipstick.
CAUTION
If the fuel level indication on the dipstick is
lower than 1/4, take-off is not recommended.
29. Upper inspection door
a. Check engine oil quantity – 10 quarts full, 8 quarts
minimum for flight.