EasyManua.ls Logo

Enterasys C5K125-48P2 User Manual

Enterasys C5K125-48P2
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
How to Use This Guide
UsethisguidetoquicklysetupyourEnterasys
®
C5switch.
EnterasysNetworksrecommendsthatyourefertothe
EnterasysC5GigabitEthernetSwitchHardwareInstallationGuidefor
specificationsandsafetywarnings.
ThelatestC5documentationislocatedat:
www.enterasys.com/support/manuals
Hardware Components
Thefollowingfiguresshowtheseveraltypesoffrontpanelport
andrearpanelconnectionsonyourC5switch.
Figure 1 C5 Switch Front Panels
C5G124-24, C5G124-24P2
C5G124-48, C5G124-48P2
C5K125-24, C5K125-24P2
C5K125-48, C5K125-48P2
C5K175-24
Figure 2 C5 Switch Back Panels
Non-PoE C5 Switches
PoE C5 Switches
Key
1
Switch status LEDs
8
Console port
2
RJ45 10/100/1000 Mbps ports
9
Stack connection ports
3
SFP slots
10
Rotary switch
4
SFP+ slots
11
Password reset button
5
RJ45 port status LEDs
12
AC power input connector
6
SFP port status LEDs
13
Redundant power supply
7
SFP+ port status LEDs (RPS) connector
Handling the Switch
Topreventelectrostaticdamage,attachanelectrostaticdischarge
(ESD)wriststraptoyourwristbeforehandlingtheswitch.
Unpacktheswitchasfollows:
1. Removethepackingmaterialprotectingtheswitch.
2. Removethetapesealonthenonconductivebagtoremovethe
switch.
3. Performavisualinspectionoftheswitchforanysigns
of
physicaldamage.ContactEnterasysNetworksifthereareany
signsofdamage.See“GettingHelp”formoreinformationon
contactingEnterasysNetworks.
Stacking Switches
UptoeightC5switchescanbestackedtogetherandconnectedby
highspeedstackingcables,whichallowtheentirestacktooperate
withasingleIPaddress.
TheC5supportsthefollowinghighspeedstackingcablesonly,
whichyoumustorderseparately:
•STKCABSHORT
•STKCABLONG
•STKCAB2M
•STK
CAB5M
Forcompleteinformationaboutstacking,refertotheEnterasysC5
GigabitEthernetSwitchHardwareInstallationGuide.
Connecting Power to the Switch
Youcanconnecttoasingle,primarysourceofpower,ortotwo
sourcesofpowerforredundancy.Theexampleusedhere
describesconnectingtotwopowersources.
Thefollowingredundantpowersuppliesareavailabletobe
purchasedfromEnterasysNetworksforconnectiontoaC5
switch:
•STKRPS150PS,a102
156wattDCpowersupplycapableof
providingpowertoafullyloadednonPoEswitch.
•STKRPS1005PS,a1005wattDCpowersupplyrecommended
forfullPoEcapability.
TopowerupyourC5switch:
1. Attachthepowercordfromyourredundantpowersupply
intotheC5switch’sredundantpowerreceptacle.
2. AttachtheACpowercordtotheC5switch’sACpower
receptacle.
3. PlugtheredundantpowersupplyandtheC5switchAC
powercordsintodedicated,groundedACoutlets.
4. Oncepowerisconnected,verifythattheCPU(system)LED
turnsamberuntiltheC5switchfinishesitsinitialization.
Iftheinitializationprocess
issuccessful,theCPULEDturnsgreen.
IftheCPULEDdoesnotturngreen,refertotheEnterasysC5
GigabitEthernetSwitchHardwareInstallationGuidefor
troubleshootinginformation.
Caution: The switch can be damaged by electrostatic discharge.
Note: You can stack a C5 switch only with other C5 switches.
Electrical Hazard: Only qualified personnel should perform
installation procedures.
Completing Switch Setup and Downloading the Latest
Firmware
OnceyouhaveconnectedpowertotheC5switchandverified
LEDactivity,youcancompletethesetupprocessasfollows.Refer
totheEnterasysC5GigabitEthernetSwitchHardwareInstallation
Guideformoreinformation.
1. DeterminethelatestC5firmwareversionbyvisitingthe
EnterasysNetworksdownloadsiteat:
http://secure.enterasys.com/services/support/downloads/software
2. Connecttheswitchtothenetwork.
3. Connectamanagementstationtotheconsoleport.
4. Verifythatthenetworkdevicesconnectedtotheswitchports
arepoweredon,andthateachlink/activityLEDison(solid
greenorblinkinggreen).
5. Atthedeviceconnectedtotheconsoleport,performthe
following:
a. Enteradminfor
Username.
b. AtthePasswordprompt,pressENTER(RETURN).
c. Atthecommandprompt,determineifthelatestfirmware
imageisloadedontheswitchbyenteringthiscommand:
show version
d. Iftheoutput(underFWVer sio n)displaysanolderversion
numberthanthatdeterminedinstep1,downloadand
activatethenewversionasdirectedonthedownload
website.(Alternatively,youcanusetheCLIcommands
listedinTable 1.)
Basic Setup Commands
Table 1listsCLIcommandsthatarerequiredforsettinguptheC5
switchwiththelatestfirmware.Table 2listsadditional
configurationcommandsforyourC5switch.Forthecompletelist
ofCLIcommands,seetheEnterasysC5CLIReference.
Table 1 Required CLI Setup Commands
Step Task CLI commands
1 Set a new password
set password [username]
2 Set the switch IP address
set ip address ip-address
[mask ip-mask] [gateway
ip-gateway]
3 Download, activate, and
verify new firmware on the
switch using TFTP copy
Note: You can reboot the
system immediately with the
set boot system command,
or reboot later with the reset
command.
copy
tftp://tftp_server_ip_address/
filename system:image
set boot system filename
show version
Table 2 Optional CLI Setup Commands
Task CLI commands
Save the active configuration
save config
Enable or disable SSH
set ssh enable | disable
Enable or disable Telnet
set telnet {enable | disable}
[inbound | outbound | all]
Enable or disable HTTP
management (WebView)
set webview {enable | disable}
Enable or disable SNMP port link
traps
set port trap port-string
{enable | disable}
Set the per port broadcast limit
set port broadcast port-string
threshold-value
Configure a VLAN
set vlan create vlan-id
set port vlan port-string
vlan-id modify-egress
Set a Syslog server IP and severity
set logging server index
ip-addr ip-addr severity
severity state enable
Specifications
Foracompletelistofspecifications,seetheEnterasysC5Gigabit
EthernetSwitchHardwareInstallationGuide.
Interfaces
Switch Dimensions
Size: 44.1Wx4.4Hx36.85Dcm
17.4Wx1.7Hx14.5Din
Power Consumption
InputVoltage:100to240VAC
Temperature and Humidity
Operatingtemperature:0°Cto50°C
Storagetemperature:‐40°Cto+70°C
Operatingrelativehumidity:5%to95%
Getting Help
Configure and enable a RADIUS
server
set radius server index
ip-addr port [secret-value]
{realm {management-access |
any | network-access}
set radius enable
Table 3 C5 Interface Descriptions
C5G124-24 24 10/100/1000Base-T ports
Four combo SFP ports
C5G124-24P2 24 10/100/1000Base-T 802.3af and 802.3at
PoE-capable ports
Four combo SFP ports
C5G124-48 48 10/100/1000Base-T ports
Four combo SFP ports
C5G124-48P2 48 10/100/1000Base-T 802.3af and 802.3at
PoE-capable ports
Four combo SFP ports
C5K125-24 24 10/100/1000Base-T ports
Two combo SFP ports
Two SFP+ ports (support 1G or 10G interfaces)
C5K125-24P2 24 10/100/1000Base-T 802.3af and 802.3at
PoE-capable ports
Two combo SFP ports
Two SFP+ ports (support 1G or 10G interfaces)
C5K125-48 48 10/100/1000Base-T ports
Two combo SFP ports
Two SFP+ ports (support 1G or 10G interfaces)
C5K125-48P2 48 10/100/1000Base-T 802.3af and 802.3at
PoE-capable ports
Two combo SFP ports
Two SFP+ ports (support 1G or 10G interfaces)
C5K175-24 24 SFP ports
Two SFP+ ports (support 1G or 10G interfaces)
World Wide Web www.enterasys.com/support/
Phone 1-800-872-8440 (toll-free in U.S. and Canada)
or 1-978-684-1888
To find the Enterasys Networks Support toll-free
number in your country:
www.enterasys.com/services/support/contact/
Internet mail support@enterasys.com
To expedite your message, type [Switching] in the
subject field of your message.
Latest image and
release notes
www.enterasys.com/services/support/downloads/
software/
Table 2 Optional CLI Setup Commands (Continued)
Task CLI commands
Question and Answer IconNeed help?

Do you have a question about the Enterasys C5K125-48P2 and is the answer not in the manual?

Enterasys C5K125-48P2 Specifications

General IconGeneral
PoE SupportYes
Switching Capacity176 Gbps
Rack MountableYes
MAC Address Table Size32, 000 entries
Jumbo Frame SupportYes
ManageableYes
Layer 3 RoutingYes
VLANs4096
Routing ProtocolOSPF, RIP, BGP
Ports48

Summary

How to Use This Guide

Hardware Components Overview

Handling and Stacking Switches

Connecting Power and Initial Setup

Technical Specifications and Interfaces

Safety and Regulatory Compliance

Laser Safety Information

Related product manuals