63
ENTRON Controls, LLC. 700230D
63
5.4 I/O Programming
[Retraction] Retraction
A 24 VDC output occurs between the selected Programmable Output and SVC when the Re-
traction input is connected to FSC either momentarily (Retraction set to MOMENTARY in the
Config Menu) or continuously (Retraction set to MAINTAINED in the Config Menu). Must be
used in conjunction with Retraction input. This output must be active for welding to proceed.
[Step End] Step End
A 24 VDC output occurs between the selected Programmable Output and SVC when the
stepper function is enabled and the step count has reached the programmed value for the
particular step.
[Water Saver] Water Saver
A 24 VDC output occurs between the selected Programmable Output and SVC for as long as
is programmed for Water Saver in the Config Menu after input to FS1 or FS2 has been re-
moved.