16 energiSava
®
250
01423 859 395
SHOULD YOU ENCOUNTER ANY PROBLEMS
INSTALLING THIS UNIT, CALL US ON:
To manually activate or deactivate the summer bypass function
(in manual bypass mode):
Press any button to wake the remote control.
Press the button again twice. The bypass LED will flash (red).
After 2 seconds the unit will enter bypass mode for 24 hours then
automatically return to the normal running mode.
To deactivate the summer bypass mode, repeat the above steps.
Filter indicator and reset:
If on waking the remote control the filter LED flashes (green), the
filters need to be replaced. Contact EnviroVent to order new filters.
After replacement filters have been installed, wake the remote
control.
Press and hold the button for 5 seconds, the filter LED will flash green.
Press and hold the button for 5 seconds again to reset the filter, the
filter LED will flash rapidly for 2 seconds to confirm the filter reset.
Pairing an extra remote control:
Turn the unit off at the isolation point.
Restore the power to the unit. For 20 seconds from restarting, the
unit will be in pairing mode.
Press the button on the new remote control once within the 20
seconds and the remote control will pair to the unit.
If LED 2 lights green, the pairing has succeeded.

Other manuals for Envirovent energiSava 250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Envirovent energiSava 250 and is the answer not in the manual?

Envirovent energiSava 250 Specifications

General IconGeneral
BrandEnvirovent
ModelenergiSava 250
CategoryHeating System
LanguageEnglish

Related product manuals