08
07 Maintenance
All repair, maintenance and component
replacement is carried out simply and
quickly by exchanging the plug out/plug in
central cartridge.
The worn out cartridge can then be returned
to the EnviroVent factory to be recycled/
reworked.
This ‘when necessary’ cartridge exchange –
with re-worked components will ensure that
the basic fan installation will remain intact
throughout the repair cycle of the dwelling,
eliminating the wasteful disposal of plastic
and other non biodegradable material to
landll sites.
Cleaning
Your Filterless Extract Fan has been designed
for easy safe cleaning.
ISOLATE THE UNIT FROM ELECTRICAL
MAINS SUPPLY BEFORE REMOVING
ANY COVER, OR SERVICING THE UNIT
1. Isolate from mains.
2. Remove front cover. (Fig.1)
3. Pull the front cover towards you from
the bottom. It will pull towards you with
a slight hinge action from the top.
4. Push the impeller clips together with
forenger and thumb and pull the
impeller towards you. (Fig.2)
5. Wash the cover and impeller in warm
soapy water. Dry and replace as above
in reverse. (Fig.3)
6. N.B. Use damp, soapy cloth to clean
scroll (NO solvents).
Fig.3
Fig.2
Fig.1