GBS-ECO-MF-V02
22
Automatic
This communication mode is compatible with the basic work modes Weight-
Tare, Levels and Part Counting.
The scale automatically sends the weight with the trace described in the
section 'Awaiting request'.
Manual
This communication mode is compatible with the basic work mode Weight-
Tare.
When the key is pressed, if the weight is stable, the scale sends the
weight with the trace described in the section 'Awaiting request'. If the weight is
not stable, the scale starts a stable weight capture sequence. When the weight
becomes stable, the scale sends the weight. If the weight does not stabilize within a
preset time (2 seconds), the weight is not sent and the scale will display an unstable
weight error (Error 14).
TYPE B:
Awaiting request
This communication mode is compatible with the basic work modes Weight-
Tare, Levels and Part Counting.
The scale can perform a series of functions if it receives a certain request:
a.-] Scale reset:
Communication format:
Computer
request
Scale answer
<#>(0x23, 35d)
The scale restarts and, upon completing
the process, sends the string:
0000000<CR>