19
Possible
values
Default value
1 1
2
After confirming this parameter with the key, all the parameters will be
considered confirmed and the scale will restart, performing the cycle test.
5. TABLE OF METROLOGICAL SPECIFICATIONS
Max Min e n Tare
6 kg 40 g 2 g 3000 - Max
12 kg 100 g 2 g 6000 - 6 kg
15 kg 100 g 5 g 3000 - Max
30 kg / A 200 g 10 g 3000 - Max
30 kg / B 200 g 5 g 6000 - 15 kg
3 / 6 kg 20 g 1 / 2 g
3000 / 3000
- 1 kg
6 / 15 kg 40 g 2 / 5 g
3000 / 3000
- 3 kg
15 / 30 kg 100 g 5 / 10 g
3000 / 3000
- 6 kg
6. SETTING THE ZERO AND THE WEIGHT
In order to make the scale's settings, press the internal setting key on the
scale's main board, which is accessed from the scale bottom (as shown in the
section 'Connections'), when the scale is in the basic work mode or when it is
displaying dashes during the initial zero.
If you press the calibration button at this time, the scale zeroes the scale with
the deadweight currently on the platform. This process may be instant or it may