EPSON Stylus PHOTO 2100/2200 Revision B
TROUBLESHOOTING Error Indications and Fault Occurrence Causes 77
Maintenance Request Off Blink alternately 1 Blink alternately 2 This error is detected when the Waste ink counter A0 
stored in the EEPROM reaches the limit (60352 points).
The error detection timing is as follows.
• At power-on
• At data transmission
• At cleaning
• At flushing
Fatal Error Off High speed Blink High speed Blink This error is detected in any of the following cases.
1. The CR unit does not operate properly due to external 
force in any sequence/operation.
2. The PF motor does not rotate properly during PF 
motor operation.
3. The home position cannot be detected by the ASF 
sensor.
"-" : don't care High speed Blink : 0.1sec on + 0.1sec off repetition
Blink : 0.5sec on + 0.5sec off repetition Blink alternately 1 : 0.5sec on + 0.5sec off repetition
Blink 2 : 0.2sec on + 0.2sec on + 0.2sec on 0.4sec off repetition Blink alternately 2 : 0.5sec on + 0.5sec on repetition
Table 3-1.  Error Indications and Fault Occurrence Causes
Printer Condition
Indicators
EPSON Printer Window 3 Fault Occurrence Cause
Power Paper Ink 1-7