EPSON Stylus Photo R1900/R2880/R2000 Revision E
Disassembly And Assembly Disassembling the Printer Mechanism 106
Confidential
4.4.6  ASF Assy
1. Remove the Printer Mechanism. (Refer to 4.4.4 Lower Housing / Printer 
Mechanism (p.96))
2. Remove the C.B.S. M3 x 8 screw that secures the Earth cables on the right rear 
side of the printer, and remove the Earth cables.
3. Disconnect the ASF Motor connector from the Relay connector.
4. Disconnect the Relay connector cable from the ASF Assy.
Figure 4-92. Releasing the Cables (1)
5. Disconnect all the cables and the FFCs from the connectors on the Relay Board.
 CN1 : Relay FFC
 CN2 : PE Sensor cable
 CN4 : APG Sensor cable (lower side)
 CN5 : APG Sensor cable (upper side)
 CN6 : PF Encoder Sensor FFC
6. Disconnect the FFC bundled by the acetate tape from the CN6 to CN22 on the 
Main Board, and release it from the groove on the ASF Assy.
7. Disconnect the APG Motor cable and PE Sensor cable from the ASF Assy.
8. Peel off the PF Encoder FFC secured by two pieces of double-sided adhesive tape 
from the ASF Assy.
Figure 4-93. Releasing the Cables (2)
 Secure the two Earth cables together with the screw. 
 Referring to Figure 4-92, correctly route the Relay connector 
cable.
When performing the following steps, be extremely careful not to 
damage the cables. If having trouble disassembling, remove the 
High Voltage Module Cover to make the work easier. (refer to 4.3.3 
High Voltage Module Step2 (p87) .)