EasyManua.ls Logo

Epson Stylus Photo R1900 - Page 88

Epson Stylus Photo R1900
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus Photo R1900/R2880/R2000 Revision E
Disassembly And Assembly Removing the Boards 88
Confidential
3. Pull off the connector of the electrode cable from its terminal on the High Voltage
Module Board with long-nose pliers or the like.
4. Disconnect the High Voltage Module cable from connector CN1 on the High
Voltage Module Board.
5. Remove the C.B.P. M3 x 8 screw and remove the High Voltage Module Board.
Figure 4-38. Removing the High Voltage Module Board (2)
Wind the High Voltage Module cable on the hook one time as
shown in Figure 4-38.
Route the electrode cable as shown in the figure below.
Figure 4-39. Routing the Electrode Cable
4) C.B.P. M3x8
High Voltage
Module cable
Hook
CN1
Electrode cable terminal
Acetate Tape
Wind it on
the hook.
Electrode cable
55±2mm
A D J U S T M E N T
R E Q U I R E D
After replacing the High Voltage Module, always make the required
adjustments referring to the following.
“Chapter 5 Adjustment (p.137)