Epson WorkForce 60 - Set Absolute Horizontal Print Position ESC $ Nl Nh

Epson WorkForce 60
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2011/03/02
Revision: 1 Page: 32
5.1.7 Set absolute horizontal print position ESC $ nL nH
ESC $ nL nH Ver 1.00
[Name] Set absolute horizontal print position [Operation]
[Format] 1BH, 24H, nL, nH
[Range of Definition] 0 <= n <= 47616 (where nL <= FFH; nH <= BAH)
[Function] 1) The printing position in the positive X direction is set to:
The maximum Absolute Horizontal Position (AHP) is 209.973mm or (29760/3600 =) 8.267
inches.
From the [ESC (U] and the [ESC (U] Extended Command
AHP AHP AHP Abs Horizontal
units Value Resolution Print Position Value
__* 0.002mm( 1/5760 inch) 5760* 0 <= n <= 47616
__* 0.004mm( 1/2880 inch) 2880* 0 <= n <= 23808
__* 0.008mm( 1/1440 inch) 1440* 0 <= n <= 11904
5 0.035mm( 5/3600 inch) 720* 0 <= n <= 5952
10 0.071mm(10/3600 inch) 360* 0 <= n <= 2976
20 0.141mm(20/3600 inch) 180* 0 <= n <= 1488
30 0.211mm(30/3600 inch) 120* 0 <= n <= 992
40 0.282mm(40/3600 inch) 90* 0 <= n <= 744
50 0.353mm(50/3600 inch) 72 0 <= n <= 595
60 0.423mm(60/3600 inch) 60 0 <= n <= 496
*See [ESC (U] Extended command for APH Units for these resolution
in general when using [ESC (U]
(256 x nH + nL) x 3600
0 <= -------------------------------- <= (29760/3600)inch
AHP_units
in general when using [ESC (U] Extended
(256 x nH + nL) x Base_Unit(m)
0 <= -------------------------------------------- <= (29760/3600)inch
AHP_units
from the origin (the left margin position) on the X axis of the
position management coordinate system.
2) If the Absolute Horizontal Position specified is passed the
right margin position, then this command is ignored.
[Initial State] -
[Related Commands]
[Setting] Commands whose settings are affected by this command.
None
[Setting] Commands that change the effects of this command.
None
[Operation] Commands whose functionality is affected by this command.
None
[Operation] Commands that change the effects of this command.
[ESC (U] sets the Absolute Horizontal Position units/value.