1 - Keep pressing MENU (left key) and (tempe-
rature setting) simultaneously for 3 seconds to
access installer mode.
2 - Choose parameter to change using
and
keys
3 - Press
to change a parameter,
4 - Set the parameter using
and keys
5 - Press
to validate
6 - Press
to exit installer mode
Param. Description Values range Default value
1LA Display language
1=EN, 2=NL, 3=FR, 4=DE, 5=IT, 6=ES,
7=PT,8=CZ, 9=HU, 10=PL, 11=RO, 12=SK, 13=HR
1=EN
2CR Cycle Rate 3, 6, 9, 12 6
3OT Minimum boiler ON time 1.....5 min 1 min
4LL Lower temperature limit 5....21°C 5°C
5UL Upper temperature limit 21....35°C 35°C
6SO Type of programmation 1=7 days, 2=5+2 days 1=7 days
9LC Fail Safe 0=Disabled, 1= Enabled 0=Disabled
10BL Backlight 0=Disabled, 1= Enabled 1= Enabled
11CL Clock format 0=24h, 1=12h 0=24h
12DS Daylight saving 0=Disabled, 1= Enabled 1= Enabled
13TO Temperature o set -3.......+3°C 0
15SD Reset schedule 0, 1 (Reset) 0
16FS Factory reset 0, 1 (Reset) 0
17OP Optimum start 0=Disabled, 1= Enabled 0=Disabled
19LK Lock options 1=Partial, 2=Total 1=Partial
Technical data
Type of Control Independently mounted control for Surface mounting
Electrical protection
IP30 No protection against water ingress
CLASS II Product that does not incorporate protective earthing provision,
but a double insulation as provision against electric shock
Type of Batteries 2 batteries AA (LR06 ) 1,5 V (not supplied)
Temperature range 5-35°C
Action Micro-interrupt, Type 1 .C
Rated current
Rated voltage : 24-230V~, 50-60Hz - Max rated current for Resistive load : 3A
Max rated current for Inductive load : 1A
Environment Pollution degree = 2 (standard household conditions without conductive dust)
Regulation class
(according 811/2013)
Class IV Rated impulse voltage 2500 V
Energy e ciency gain (contribution to seasonal space heating energy e ciency) 2%
Class of Software Class A
Overvoltage Category according IEC/EN 60730-1
II
Supplier ADEO Services - 135 Rue Sadi Carnot, CS 00001, 59790 - RONCHIN - FRANCE