OVERVIEW:
The M700 Control Module (M700C) contains
the system’s user interface and also provides
the power and the distributed intelligence to
all downstream modules connected to it. The
M700C can be used with the Feeder Module
alone, a cutter module alone, or with both
the Feeder Module and a cutter module for
automated material processing.
TECHNICAL DATA:
Programmable Material Specications:
Minimum programmable feed length: 0.100”
(.254cm)
Maximum programmable feed length:
99,999.0 (in or cm)
Maximum programmable quantity:
99,999 pieces
Module Dimensions (L x W x H):
16” x 9.5” x 8”
(40.64cm x 24.13cm x 20.32cm)
Module Weight: 14.5lb (6.6kg)
PERFORMANCE:
Supported Modes
Continuous Mode
Single Piece Flow Mode
Jobs/Batches:
Up to 100 programmable Jobs;
1-20 Batches per Job
Feed/Cut Parameters:
Feed Rates: 10 selectable rates (0-9)
Cut Rates: 10 selectable rates (0-9)
Cut Time: 0.2 seconds - 3.0 seconds
POWER:
The system employs auto range selection
and operates over the input power range of
100–240VAC at 50/60Hz.
FUSES:
The system uses (2) 6.3A 5x20mm fuses. The
M700C ships with fuses already installed.
Fuse Replacement:
1. Locate the fuse box on the rear side of the
M700C unit.
2. Using a small at head screwdriver
carefully release the fuse box latch.
3. Using the same screwdriver, carefully
remove the fuse cartridge, and replace both
fuses.
OPTIONAL PARTS
Foot Switch: IR3323
Job Manager Application: IR3325
SETUP AND OPERATION:
Plug in the M700C unit to power source.
Turn on the unit using power rocker switch
located on the back of the unit.
When power is on, the screen will display
the Main Menu (after a brief Eraser Company
splash screen).
SplashScreen
THE ERASER COMPANY
M700
FIRMWARE VX.XX.XX
MainMenu(1-4)
1. System Status
2. Manual Mode
3. Run Job
4. Create/Edit Job
Pressing ENTER will display the remainder of
the Main Menu options:
M700 CONTROL MODULE (AR3300)
Jobs/Batches:
Up to 100 programmable Jobs; 1-20
Batches per Job
Feed/Cut Parameters:
Feed Rates:10 selectable rates (0-9)
Cut Rates:10 selectable rates (0-9)
Cut Time: 0.2 seconds - 3.0 seconds