A1018s/A1018sc Standard Electrical Repair
4/00021-2/FEA 209 544/16.B 7 (42)
2.5 The phone gets serv, but can´t connect a
call.
Open the phone and check for liquid damages.
Check the soldering at the components around N202 (class C) and N550 (class
C)(both at fig. 2.1).
If the fault remains, send the phone to the next repair level.