Trouble Shooting Guide, Advanced
4/00021-3/FEA 209 544/25 C
Ericsson Mobile Communications AB
14(78)
The table below Table. 4.1 shows the limits for the ADC-values at the calibration.
When calibrating there must be an accuracy of ± 15 mV
DC
.
Battery voltage min max
3.2 V
DC
20 34 hex
4.1 V
DC
73 87 hex
Table. 4.1
You can check the ADC-values.
Go to Logic\Selftest.
If Power ASIC passed, the values are in range.
If Power ASIC failed it is probably due to N700.