GH688,GA628, Standard Electrical Repairs
4/00021-2/FEA 209 544/1.G 31 (112)
5.3.2 The display is totally empty or the contrast is low.
Give the board power and start it up without a display mounted.
GH 688
The front side of the board is shown in fig. 5.1
Measure the voltages at V608 (class A) and V611 (class A). The GH 688 uses dis-
plays of two different brands, Philips and Seiko. Fig. 5.2 and 5.3 shows typical volt-
age values for both brands.
Fig. 5.1
Applies for KRC 114 245 and KRC 114 277 (Philips display):
Fig. 5.2