RBS 2308 and RBS 2309 User’s Guide
3.
If 3-wire is used, set the ground
selector to 3-W.
P010510B
3-W
48 V
48 V_RTN
PE = Protective Earth
PE
4. Ensure that the prote
ctive earth is properly connected.
5.
Put back the MBU cover.
5.4.5 Replacing the Flas
h Card (If Applicable)
This section descr
ibes how to replace the existing flash card in the IXU. This is
done only if a flash
card, preloaded with site-specific data, is provided.
Note: Using the OM
T, always reload the software and install the appropriate
IDB after moving a
used flash card to another cabinet. This ensures
consistent soft
ware and correct configuration.
For information
about preloading the flash card, see Chapter Maintenance.