5.4 Specifications
Note: Test Conditions:
Ambient temperature : 20°C Water inlet 15°C, Water Outlet 55°C
Working conditions: -7 to 43°C
Maximum water temperature storage: 60°C
Water temperature range: 12°C -60°C
Water pressure operating range 0.1-.07MPa
5.5 PERFORMANCE
5.5.1 Performance Assumptions
Heating Capacity
The unit absorbs energy from the air taken in through the inlet ductwork. If the air inlet temperature is
low, heating capacity will show a variation from standard conditions.
3 Minutes Protection
When the unit stops, if you try to restart the unit (or turn the unit on manually) immediately, the unit will
not run for 3 minutes. This is built in protection for the compressor.
Model
ECOCENT
250
T
ECOCENT
250
T2
Heating
capacity
kw
3
3
Water
tank
volume
L
250
250
Power
input
W
790
790
Running
current
A
3.6
3.6
Power
supply
V/Ph/Hz
220-230/1/50
220-230/1/50
Compressor
number
1
1
Compressor
type
Rotary
Rotary
Rated
outlet
water
temperature
55
55
Max
outlet
water
temperature
60
60
Air
volume
M
3
/h
450
450
Air
pressure
Pa
60
60
Duct
diameter
mm
Φ
150
Φ
150
Noise
dB(A)
49
49
Water
inlet
size/outlet
size
inch
G
3/4"
G
3/4"
Net
dimensions
mm
Φ
640
×
1610
Φ
640
×
1610
Package
dimensions
mm
705
×
705
×
1750
705
×
705
×
1750
Net
weight
kg
84
88
Gross
weight
kg
103
107